If there has been a recent power outage, the clock will have stopped and youll need to reset the clock to the correct time.
Tork timer not keeping time | Mike Holt's Forum You can manually engage it by turning it and then it will run and even SHUT OFF when its supposed to. Date Listed: 18/02/2023; . Take them off and inspect them and look for twists in them. Look at the copper tabs on the back and observe the action as you flip the switch manually on and off. Why it always stop around 10pm by itself and not moving again? To set it, you just move the on/off "trippers" where you want them. Theres really only 3 causes as to why your pump wont turn on/off. Yet another reason why timers dont work properly is the yellow clock wheel is not located or seated properly. However the new breaker is in a constantly tripped position. Report B BadOleRoss 0 LifeTime Supporter Apr 30, 2011 393 Lynchburg VA Aug 21, 2012 #8 Generally, plug-in-outlet timer has gone bad, then it cannot be fixed. The problem lies where the power dies, youve probably heard that before. Some of the replacement motors make it past quality control with the incorrect gear setup. the problem lies, where the power dies as they say. Hi John, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. I have an Intermatic 277/208v T104 timer controlling two 60Hz 120v outdoor lighting circuits. Hello, I notice today that my pump wasnt running so I opened the pool breaker panel where the timer is and noticed the breaker was tripped. However, intermittently after the ON tripper switches pump on the pump will stop. Theres power to the pump using the manual override. This product can be controlled with your voice through Alexa-enabled devices such as Amazon Echo and Amazon Tap. Put a meter on the wires or trace them back to find out their voltage and source. The clock not turning on your Intermatic pool timer is a common issue. Shut off the breaker and check that the wires are tight on the terminals, and that the white wires are connected well on the motor (depress the tab at the top to inspect behind the time clock). You will have live wires exposed and they can kill you if you touch them. We had a storm last week and the yard flooded my pool so I went and switched the pool off at the breaker so it would not come on with the tabs until we were able to handle the pool. How can I fix this? Timer not tripping pump on. You can replace the timer motor only, or the entire clock, both fairly easy to swap out. 4 Beds. Found the answer. Ideally, the switch would be placed after the timeclock, not before. You can replace the entire mechanism or the gears. Hi Casey, perhaps the cord or wires are broken?
Simple Ways to Set a Pool Timer: 11 Steps (with Pictures) - wikiHow No matter what caused the issue, there is typically an easy fix! "author": {
You need extreme care in this next step.
How to Install the Trippers on Intermatic Timers | eHow We had a few power outages the last couple of weeks, but Ive reset the time and it continues to lose time. PF1202T Freeze Protection Control Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Is there a control board, PCB in the panel that could have problems? Ill do the same. Hi Cody, if you cannot see any obstruction in the motor gears, or any such mechanical issue, then I would assume an electrical issue, perhaps the wrong voltage for the clock. Not sure if i need to check out the wiring, but it is a bit frustrating. How can it keep time if lever is in off position (manual lever). If the pump comes on, you definitely have power to the timer. Hi Catherine, turning it on manually should not have damaged anything, so go easy on yourself It might have just been time to go. Is it Necessary? Does it need lubricant or something? Eldon, the breaker should not be bad, but the timeclock may be wired incorrectly. Turn the manual on/off switch. I have removed the ON TRIPPER and turn the motor on at the pump and it never trips the GFCI. "wordCount": "1259",
Secure wire conduit to the knock out with the proper conduit connectors, and first connect the green ground wire to the green ground screw labeled GRD. Hello have a question some what related. Theres an issue with the wiring between the circuit breaker and the timer. If you dont think the mechanism is the issue, move onto the next step.
Read Book Tork Trippers Manual Guide Pdf For Free - twiki.skotos Miriam, I would check that the timer dogs are pushed fully onto the dial, and the dial is tight also check the screw for tightness in the center of the dial. The pool timers I have had down there . Ive reset the time 5 times and just realized that its going counter clockwise. Home / Pool Repairs / Equipment Repairs / Intermatic Pool Timer Troubleshooting. My time clock has an ant infestation! Until it came in, I manually turned on and the tripper turned it off. For additional tripper pairs on CLOCK-DIALorder 156T1978A. It stays on until I turn off the circuit breaker. If you cant, is the manual switch stuck or jammed? Now Im having to turn my pool pump on and off manually. Posted by 4 years ago. Sometimes we suspect the timer is the issue but it turns out its really the pump or the wiring between the pump and the timer. Move the start and stop pins to appropriate times for swimming pool filter operation. Check the wiring also, looking for broken wires or loose connections, which could explain the breaker tripping as well. GFCI breakers trip at a very low threshold, doesnt take much. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Why is my water heater timer not working? - Quick-Advices HI Ben, yes just remove the OFF tripper, and the clock will always be ON. Please advise. Once you remove the water, you can use your pool brush on a pole, to gently push the pillows back to the center. If you have gone back after a few hours and the pins have moved that means you have electrical power to your timer and it is working. Confused. Did you try to flip the switch of the timeclock? My Polaris booster pump ONLY turns on via the trippers. Open following links to identify timer and then add a comment. When I turned it back on now the pool clock goes backwards. Thank you.
2425 Glenview Dr, HOLLISTER, CA 95023 | MLS# ML81913834 | Redfin TO SET TIME-OF-DAY:Pull CLOCK-DIALoutward. I can, however, hear an intermittent click as if the mechanism is trying to switch on. No luck. Now try to jiggle it on and off. . Also, once it reaches the tripper, the gears in the window no longer move. Hello, newer pool guy here. Terminal A (farthest to the left side) is not connected to anything. Ask Your Own Pool and Spa Question See the point above if it is. Hi Matthew T104 can only turn one pump on and off. Pool co says T104 timer needs replacement and filter cartridge. Reset the clock to the correct time. No high loop or air gap in the old under-the-sink dishwasher drain, Consider radiant underfloor heating system, Several Important Steps Homeowners Can Take To Protect Their Furnace, 4 Kinds Of Chemical Drain Cleaners That Clear Out Drains and Their Hidden Dangers. Or be loose and not making good contact. It should loosen up after a few goes when the grease and gunt dissolve. Do you have an answer to why my pump wont turn off or on? #9. Intermatic pool timers allow you to set specific run-times for your pool filter pump, booster pump, and waterfall pump, so they operate at the most convenient time, or during non-peak energy hours. Trippers are not installed properly Re-install trippers on dial 2. As it get cooler you can cut it down to 5 or 6 hr a day . Sound right? The position of the metal bar forces the gear next to it to turn one way or another. Hi Doug, Check the wiring. How about the GFCI outlet TEST button, is it tripped? There is also a light switch for the lighting in the pool in the control panel and when i turn on the switch the light in the pool turns on. Followed all directions and even watched YouTube troubleshooting videos. Check the wire connections to be sure they are tight, and look for any burnt wires. The timer motor cover (the oval silver box with the printing) can be pried off with a sharp screwdriver. Replace a new T104. Why do we stock so many pool parts? Go for it, a little maintenance expense. 2,767 Sq. Resolved! If the clock was already showing the correct time, check the On/Off Trippers (Pointers) are set to the correct time and are not loose. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Still no luck. Any guidance on how to fix this? Put them back on and tighten them. I see a little groove worn in the corner of the on/off switch where the off timer dog touches. The trippers will "trip" the analog clock to turn on and off automatically at the set times. Faulty Pump or Wiring from the Timer to the Pump. To inspect, shut off power at the breaker, and push on the clip at the top of the box, to allow the mechanism to fall forward, and then you can inspect the vertical copper bars, and see how they shift and come apart (or not), when the switch is turned to off. Electricity is dangerous and can kill you if you dont know what youre doing. Since it came out of the box today, it probably is not trash in the gears.It seems the plastic gears and/or the coil in the clock mechanism are not strong enough to engage the on/off points or not for long. Make sure the middle time pointer is tight. I replaced the pump and still nothing is moving. It is still moving and it will trip off but not on. If so, is there power coming into the clock (on the line terminals)? If it doesnt improve, inspect the contacts behind the time clock for insect infestation. Beverly, it could be, but the cost of running wiring to the garage may be more than replacing it every 15-20 years. My intermatic timer is about two years old as well.
Pool Timer Not Turning ON or OFF!! Watch these tips and - YouTube Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. Or is there anything else I can check? Hi Joe, could be time, for new timer. I have an intermatic T20004R and my timer is working because it is keeping the correct time. If dial is rotating correctly, but water heater never turns on-off, then trippers might be bad. I made sure the trippers were fully inserted and tight. If your timer pins have not moved that means there is no power to the timer or the timer has failed and need to be replaced or possible manual over ride switch for the timer is off. We may earn a small commission. You most likely just need to now set the pins and the clock and your timer will work. Using a tester i noticed that there is no power going thru the lines for the pump and salt system. Much like your timer pointer, the trippers can become loose and move around as well. A timer replacement would be required. We are on our third timer. There are many reasons why your pool timer may not be working. . DEWENWILS Outdoor Outlet Box. The power should run from the breaker, to the timer, to the pump. The circuit is protected by two ganged breakers. Can breaker be bad? I copied the wiring config exactly and my clock gears still arent moving, so now Im thinking the wiring was wrong all along. Hi, I got the same problem as my clock not working. See the next section in this article for that. Then number(time of day) that you line up with the time marker will be the time that you are setting your timer to. If after verifying you have power to the timer, then check these things to further troubleshoot. Hi, if you have a variable speed pump, you do not need to use the external timer anymore, but should program with the on-board pump timer. You will feel the wheel pull out about an 1/8 of an inch and then you will be able to rotate the timer wheel. Sometimes the on/off switch on Intermatic and other mechanical timers can get tight. This is hard to check if you are not qualified. 1-48 of 242 results for "pool timer trippers" RESULTS. Hi Fred, the only thought I have is that the cord should not be unplugged to turn off the pump, instead, rotate the dial until it turns off, because I dont believe there is a switch to turn off the timer. So what would be the problem? Line is incoming, Load goes to the pump. Im ready to send my back for a replacement. Maybe 2/wks ago I replaced it with a new timer, and it's doing the same thing.
First time pool owner, Pool timer and trippers not working properly Please let me know if you find the solution! In this post, we discuss a few quick and easy ways to troubleshoot your pumps Intermatic timer clock problems. Can the pool timer be placed inside the garage to protect it from the harsh weather. Or fold the cover to one side if needed. "url": "https://intheswim.com/",
Any other thoughts? If thats all ok, shut off breaker and depress tab at the top, to release the mechanism from the box, and look at the copper tabs in the back. Perhaps you had a power outage during the night? You can always call us at 815-675-7000 M-F 8am-4:30pm CST and speak with a live technician. Lately, the timer mechanism on my old T104R does not move. "publisher": {
I can manually turn it on with the lever at the bottom. My Intermatic Pool Timer still works like normal but, when it gets to the time set to turn pump on or off it doesnt. View community ranking In the Top 5% of largest communities on Reddit. Replace them if they appear to be bent. My timer works good it turns on and off when I set the time. Can I spray the timer while there is electricity going in the timer box? 1. You dont have two OFF trippers, right? With this model can I control both of these motors with two different on and off times. See the wirig diagram in the owners manual here: https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf Clock motor power, as shown in the wiring diagram, comes from terminal 1 and also terminal 3. by pool co. , so wondered about the cost. If none of the above suggestions resolves your issues or the issues continue to persist, it may be a good idea to purchase a new Intermatic timer for your pump. A couple of weeks in, I noticed it was not keeping time. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Intermatic timers are a great addition to your pool set up but they can go wrong. Also be sure that the front dial is engaged with the gear located behind the dial. My timer runs, then after it reaches the off tripper, it stops, and never goes past the off tripper. HELP! South Sea Island Accommodation: Was a good island when all the day trippers left - See 160 traveler reviews, 205 candid photos, and great deals for South Sea Island Accommodation at Tripadvisor. The other gears are not and the pump will not turn on or off unless done manually. Check the motor, and be sure the label is not printed 50 hz. The back of the timer dog has a tab that flips the switch, check the alignment of both, the dog may not be contacting the switch with enough surface to flip it on? My pump has a plug. the timer was directly plugged into a gfci and the pump directly into the timer. Your timer is on a 24-hour cycle. Any advice? If the trippers are loose, then they could slip and cause issues with the pump turning on/off at the correct times. If unsure, the White (Neutral) wire connects to the neutral buss bar in the breaker panel, and the Black (Line) wire would connect to the circuit breaker. If you run rope/twine through the Air Pillow grommets, you can tie them to each other and run the rope/string to opposite sides of the pool, tying it off, so they will stay in the middle. "
Clean the gears with a toothbrush if you see debris or gunk in them. For Sale: 2 beds, 2 baths 1152 sq. Phil. I have a inground pool with T10003RT4 control panel. Thanks in advance! So I connected all leads as on the directions and the clock and on off manual switch working.Not sure if timer was never connected or someone disconnected it. So either the tripper is broken (or installed out of alignment) or the tab (s) on the on/off switch are broken. I dont see any debris blocking the off dog. The timer quit after a nearby lightning strike. Hi Jennifer, power down (shut off the breaker) again, to see if it will switch back. There should be an off pin and an on pin. Required fields are marked *. I had a power surge last night ( funny as there was no storms here ) and now my intermatic T104M timer doesnt work anymore. Turn the metal bar until it contacts one of two plastic side tabs. Switch the breaker off at the power board. I have a Model T104P and have a new green on tripper attached. The gears in mechanical timers can get damaged. 2nd black goes to -2 Align the bar with the current time and push it back into place.